International Journal of

ADVANCED AND APPLIED SCIENCES

EISSN: 2313-3724, Print ISSN: 2313-626X

Frequency: 12

line decor
  
line decor

 Volume 9, Issue 6 (June 2022), Pages: 63-69

----------------------------------------------

 Original Research Paper

 Effect of VLAN configuration on IEC 61850 sampled values

 Author(s): Sung-Ho Hwang *

 Affiliation(s):

 Division of Electronics, Information and Communication Engineering, Kangwon National University, Samcheok, South Korea

  Full Text - PDF          XML

 * Corresponding Author. 

  Corresponding author's ORCID profile: https://orcid.org/0000-0002-2824-9399

 Digital Object Identifier: 

 https://doi.org/10.21833/ijaas.2022.06.008

 Abstract:

IEC 61850, the standard for communication in power utility, has solved the interoperability problems between different vendors in substation communication networks (SCNs). However, most studies on SCN that use IEC 61850 were conducted using computer-based simulations or commercial equipment with fixed functions. In this study, an experiment on an SCN was conducted using real equipment such as a network switch, Raspberry Pi, and a mini PC. A cyclic data model was used for the traffic generation of sampled values (SVs) according to IEC 61850. The effect of applying a virtual local area network (VLAN) in the SCN on the transfer time and throughput of the SV frames was measured. In addition, when using IEEE 1588 in the time synchronization process, it was verified that the clock offset remained unaffected irrespective of the use of VLANs or changes in the sampling frequency. The experimental results can serve as guidance for the actual planning and construction process of SCNs. 

 © 2022 The Authors. Published by IASE.

 This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).

 Keywords: IEC 61850 VLAN, SCN, IE 4000

 Article History: Received 15 December 2021, Received in revised form 26 March 2022, Accepted 30 March 2022

 Acknowledgment 

No Acknowledgment.

 Compliance with ethical standards

 Conflict of interest: The author(s) declared no potential conflicts of interest with respect to the research, authorship, and/or publication of this article.

 Citation:

 Hwang SH (2022). Effect of VLAN configuration on IEC 61850 sampled values. International Journal of Advanced and Applied Sciences, 9(6): 63-69

 Permanent Link to this page

 Figures

 Fig. 1 Fig. 2 Fig. 3 Fig. 4 Fig. 5 Fig. 6 Fig. 7 Fig. 8

 Tables

 Table 1 Table 2 Table 3 

----------------------------------------------    

 References (5)

  1. IEC (2003). IEC61850: Communication networks and systems in substations, Part 5: Communication requirements for functions and device models. International Electrotechnical Commission, Geneva, Switzerland.   [Google Scholar]
  2. Ingram DM, Schaub P, and Campbell DA (2011). Multicast traffic filtering for sampled value process bus networks. In the IECON 2011-37th Annual Conference of the IEEE Industrial Electronics Society, IEEE. Melbourne, Australia: 4710-4715. https://doi.org/10.1109/IECON.2011.6120087   [Google Scholar]
  3. Schossig T (2014). Commissioning of IEC 61850 substation utilizing new tools. In the 12th IET International Conference on Developments in Power System Protection, IET, Copenhagen, Denmark: 1-5. https://doi.org/10.1049/cp.2014.0038   [Google Scholar]
  4. Ustun TS, Aftab MA, Ali I, and Hussain SS (2019). A novel scheme for performance evaluation of an IEC 61850-based active distribution system substation. IEEE Access, 7: 123893-123902. https://doi.org/10.1109/ACCESS.2019.2937971   [Google Scholar]
  5. Zhang Z, Huang X, Keune B, Cao Y, and Li Y (2015). Modeling and simulation of data flow for VLAN-based communication in substations. IEEE Systems Journal, 11(4): 2467-2478. https://doi.org/10.1109/JSYST.2015.2428058   [Google Scholar]